How Long Will My Battery Last in an Outage?

Enter your battery's capacity (in kWh, or volts and amp-hours) and tick what you will plug in when the power goes out. You get how many hours it lasts with a safety margin, how much of the battery actually reaches your appliances, whether the inverter can handle the fridge starting up, and what size battery you would need for the hours you want to cover.

Works anywhere in the world, wherever you are.

The battery

Its capacity is given as

Look for “usable energy” or “capacity” on the maker's datasheet.

Battery type

How much of the battery you use. Conservative value: 90% lithium, 50% lead-acid. Use your maker's figure.

Energy lost converting to 120 V. Typical: 85% to 95%.

What the inverter uses just by being on. Check the manual.

For heat, an aging battery and losses. We recommend 20%.

What you will plug in

The watts are typical examples: replace them with each appliance's label. Set 0 for what you will not use.

QtyWatts

Another appliance (from its label)

Motors and compressors start higher. If you do not know, leave the same number.

The inverter (optional)

To tell you what size battery you would need.

If you depend on medical equipment (oxygen concentrator, CPAP, a fridge for insulin), use the watts on its label, leave extra margin and check with your health provider or the device's maker. Do not rely on this estimate alone.

It lasts, with margin

8 h 45 min

Without margin (ideal): 10 h 57 min · 370 W

Total load
370 W
Usable energy
4.5 kWh
Reaches your appliances
4.05 kWh
Battery for 24 hours
13.7 kWh
Peak at start-up
645 W
Without margin (ideal)
10 h 57 min

Where it comes from

Nominal capacity
5,000 Wh
× DoD = usable (90%)
4,500 Wh
× efficiency = delivered (90%)
4,050 Wh
÷ load (appliances + idle)
370 W
= ideal hours
10.95
× (1 − margin) = hours with margin (20%)
8.76

To compare with a generator, use the Generator Fuel Calculator. To recharge from the sun, the Solar Savings Calculator. For what each appliance uses, the Appliance Cost Calculator. And to read your power bill, the LUMA Bill Analyzer.

Connecting a battery or inverter to the house panel is a job for a licensed electrician. This page only estimates hours and size; it gives no installation instructions.

This is an estimate from basic physics, not a guarantee. Real runtime drops with heat, old batteries, appliances that draw more at start-up and, for lead-acid, heavy loads. It is not electrical advice.

About this calculator

How it is worked out

Nominal capacity: the battery's kWh times 1,000, or volts × amp-hours × the number of batteries. A 12 V, 100 Ah battery stores 1,200 Wh.

Not all of that energy can be used. Depth of discharge (DoD) is how much you can draw without harming the battery, and the inverter loses some converting it to 120 V. Energy delivered = nominal × DoD × efficiency.

Hours = energy delivered ÷ the watts of everything you plug in, plus what the inverter uses just by being on. Last, we take off a safety margin (20% unless you change it), because heat, an aging battery and motors starting up cut the real runtime.

Example

A 5 kWh lithium battery at 90% depth of discharge with a 90% inverter: 5,000 Wh × 0.9 = 4,500 Wh usable, and 4,050 Wh reaches your appliances.

You plug in the fridge (150 W), two fans (140 W), the router (15 W) and four LED bulbs (40 W): 345 W, plus 25 W of inverter idle draw, makes 370 W.

4,050 ÷ 370 = 10.95 hours in theory, about 10 h 57 min. With the 20% margin, count on 8 h 45 min. To cover 24 hours with the same load you would need about 13,704 Wh of nominal battery (13.7 kWh).

Lithium or lead-acid

Lithium iron phosphate (LiFePO4) batteries handle deep discharges; we start from a conservative 90%. Lead-acid batteries (car or deep-cycle) wear out much faster past 50%, so that is their default.

Two 12 V, 100 Ah lead-acid batteries hold 2,400 Wh, but only 1,200 Wh is usable. With an 85% inverter, 1,020 Wh gets through: 5.1 hours at 200 W, or 4 h 5 min with the margin. Your battery's datasheet rules: if it gives another depth of discharge, use it.

Start-up surge and the inverter

Appliances with a motor or compressor, such as the fridge, draw several times more for a moment when they start. If you enter your inverter's continuous and peak power, we check two things: that everything together stays under the continuous rating, and that the biggest start-up stays under the peak.

If it does not, the inverter shuts off or trips. The usual fix is to start the motor appliance first, on its own, then the rest, or to unplug what is not essential. Connecting a battery to the house panel is a job for a licensed electrician.

Important limitations

  • This is an estimate from basic physics. Real runtime drops with heat, with old batteries and, for lead-acid, with heavy loads.
  • The appliance watts are typical examples. Yours are on each appliance's label; fridges and air conditioners cycle on and off, so their average draw is lower than the label.
  • It does not replace your battery's or inverter's datasheet, or an assessment by a licensed electrician.
  • If you depend on medical equipment, check with your health provider or the device's maker; do not rely on this estimate alone.
  • We do not recommend any battery or inverter brand.

Frequently asked questions

It depends on what you plug in. At 370 W (fridge, two fans, router, four LED bulbs and the inverter idling), a 5 kWh lithium battery gives about 10 h 57 min in theory and 8 h 45 min with a 20% margin. Halve the load and it lasts twice as long.

Multiply volts × amp-hours and divide by 1,000. A 12 V, 100 Ah battery is 1,200 Wh, or 1.2 kWh. Two of them make 2.4 kWh. That is the nominal capacity; how much you can use depends on the depth of discharge.

It is the share of the battery you can use without shortening its life. Lithium (LiFePO4) allows much more than lead-acid: here we start from 90% and 50%. If your battery's datasheet gives another number, use that.

Multiply the watts of what you will plug in by 24 and divide by the efficiency, the depth of discharge and (1 − margin). At 370 W, a 90% inverter, 90% DoD and a 20% margin: 370 × 24 ÷ 0.648 = 13,704 Wh, about 13.7 kWh.

You can work it out by entering its watts as another appliance, but an A/C draws much more than a fridge and has a high start-up surge, so the battery lasts only a few hours and the inverter must handle the peak. Compare with the generator calculator before you decide.

This calculation runs in your browser and is never sent to a server. Your last values may be saved on your device only, for convenience. Results are estimates and are not financial, tax, accounting or legal advice.