Skip to content

Air Conditioner BTU Calculator

Enter the room's measurements in feet or metres, how much sun it gets, how many people usually use it and whether it is a kitchen, and the calculator tells you how many BTU per hour the air conditioner needs, in tons too, and which common unit size comes closest. It uses the chart and adjustments ENERGY STAR publishes.

Works anywhere in the world, wherever you are.

Units
How do you want to enter the area?

Inches to feet: divide by 12 (6 in = 0.5 ft).

How much sun does the room get?

600 BTU is added for each person beyond 2.

Is it a kitchen?

Recommended capacity

6,000 BTU/h

≈ 0.5 tons

Nearest common size
6,000 BTU
From the chart
6,000 BTU
Area
168 ft² (15.6 m²)

Chart calculated for 8 ft (about 2.4 m) ceilings. The sun or shade percentage applies to the chart capacity; people and kitchen are added after.

ENERGY STAR (U.S. Environmental Protection Agency), “Room Air Conditioners”: capacity-by-area chart and adjustments for shade, sun, people and kitchen. Reviewed November 2026.

A guide for a room unit (window, portable or a single-room mini-split). For central air or a whole home, the standard is an ACCA Manual J load calculation, which accounts for insulation, windows, orientation and climate; ask your HVAC technician for one.

About this calculator

How it works

First comes the floor area: length × width. ENERGY STAR says to measure in feet and turn inches into fractions of a foot (12 ft 6 in is 12.5 ft). If you measure in metres, the calculator converts the area to square feet.

That area is looked up on the ENERGY STAR chart, which runs from 5,000 BTU per hour for 100 to 150 sq ft up to 34,000 for 2,000 to 2,500 sq ft. The chart is calculated for 8 ft ceilings.

Then come ENERGY STAR's published adjustments: a heavily shaded room, 10% less; a very sunny room, 10% more; 600 BTU more for each person beyond two who regularly uses the room; and 4,000 BTU more if the unit is for a kitchen. ENERGY STAR does not say in which order to apply them: the calculator applies the percentage to the chart figure and then adds people and kitchen.

Finally, the calculator finds the nearest common unit size (5,000, 6,000, 8,000, 9,000, 10,000, 12,000, 18,000, 24,000 BTU and others), and if that one falls short, it also shows the next size up. One ton of refrigeration is 12,000 BTU per hour.

Area (sq ft)Area (m²)Capacity (BTU/h)
100 – 1509.3 – 13.95,000
150 – 25013.9 – 23.26,000
250 – 30023.2 – 27.97,000
300 – 35027.9 – 32.58,000
350 – 40032.5 – 37.29,000
400 – 45037.2 – 41.810,000
450 – 55041.8 – 51.112,000
550 – 70051.1 – 6514,000
700 – 1,00065 – 92.918,000
1,000 – 1,20092.9 – 111.521,000
1,200 – 1,400111.5 – 130.123,000
1,400 – 1,500130.1 – 139.424,000
1,500 – 2,000139.4 – 185.830,000
2,000 – 2,500185.8 – 232.334,000

Source: ENERGY STAR (EPA). Calculated for 8 ft ceilings. Before the adjustments for shade, sun, people and kitchen.

Examples

A 12 × 14 ft room has 168 sq ft, and the chart gives it 6,000 BTU. If it is very sunny, 10% more: 6,600. If three people sleep or work there, 600 more: 7,200 BTU per hour. The nearest common size is 8,000 BTU.

An open 20 × 25 ft living room and kitchen has 500 sq ft: 12,000 BTU from the chart, 4,000 more for the kitchen and 1,200 more for four people, for 17,200 BTU per hour (1.43 tons). The nearest common size is 18,000 BTU.

In metres: a 4 × 4 m room has 16 m², or 172.22 sq ft, and the chart gives it 6,000 BTU. If it is heavily shaded, 10% less: 5,400. The nearest size is 5,000 BTU; if you would rather not go short, the next one up is 6,000.

Why a bigger unit is not better

ENERGY STAR warns that bigger is not better. An oversized unit costs more, wastes energy and cools the room before it has a chance to remove the humidity, so the air feels cold but damp and clammy. In a humid climate such as Puerto Rico's, that shows.

An undersized one, on the other hand, runs non-stop and cannot reach the set temperature in the hottest hours. That is why the starting point is the chart, not “the biggest one that fits the window”.

To see what it would add to your power bill, use the Appliance Cost Calculator or the Electricity Usage Calculator with the wattage of the unit you choose.

Central air and whole homes: Manual J

The ENERGY STAR chart is for a room air conditioner. For a central system or a whole home, the standard is a Manual J load calculation from the Air Conditioning Contractors of America (ACCA), which the U.S. Department of Energy recommends to contractors, followed by Manual S to choose the equipment.

Manual J accounts for insulation, windows, which way the home faces, air leakage, ductwork and the local climate. Ask your HVAC technician to run one before quoting a central system.

Important limitations

  • A guide for a room unit based on the ENERGY STAR chart, not a load calculation. For central air or a whole home, ask for a Manual J.
  • The chart is calculated for 8 ft ceilings. With higher ceilings the room has more air to cool and may need more capacity.
  • It does not cover spaces over 2,500 sq ft, which are beyond the chart.
  • It does not account for insulation, window type, heat-producing equipment or the local climate beyond the sun and shade adjustments.
  • The common sizes are the ones seen in stores; check which capacities your supplier carries.

Frequently asked questions

A 12 × 12 ft room has 144 sq ft, and the ENERGY STAR chart gives it 5,000 BTU per hour for two people and normal sun. If it is very sunny or more people use it, raise it with the adjustments.

On the ENERGY STAR chart, 12,000 BTU per hour matches an area of 450 to 550 sq ft with an 8 ft ceiling, before the sun, people or kitchen adjustments.

One ton of refrigeration is 12,000 BTU per hour. An 18,000 BTU unit is 1.5 tons, and a 24,000 BTU unit is 2 tons.

ENERGY STAR adds 600 BTU for each person beyond two who regularly uses the room. With four people, that is 1,200 BTU more.

No. For a central system or a whole home, the standard is an ACCA Manual J load calculation, done by a technician with your home's details. This calculator is for a room unit.

This calculation runs in your browser and is never sent to a server. Your last values may be saved on your device only, for convenience. Results are estimates and are not financial, tax, accounting or legal advice.