Skip to content

Online decibel meter

Turn on the microphone and see the noise level in decibels in real time, A-weighted like a sound level meter, with the session's minimum, average (Leq) and maximum and a graph of the last 60 seconds. You can calibrate it against a reference meter, compare it with everyday sounds published by WHO and NIDCD, and download the session as CSV. Sound is analysed on your device: it isn't recorded or sent anywhere.

Works anywhere in the world, wherever you are.

Decibel meter

Sound is analysed on your device. Nothing is recorded or sent to any server.

Level now

uncalibrated estimate

Minimum

—

Average (Leq)

—

Maximum

—

Duration

0:00

Last 60 seconds · dB(A)

Frequency weighting
Response

A phone or computer microphone isn't calibrated: until you calibrate it, the dB figure is an estimate that can be off by 10 dB or more. Calibrate it against a reference sound level meter for better accuracy.

Calibrate the microphone100 dB

Place your device next to a reference sound level meter, with a steady sound (a fan, for example) and the same weighting. Type what the meter reads and press “Match”. The calibration is saved only in this browser.

Generic starting value: 100 dB. It doesn't belong to any particular microphone.

Exposure (for information only)

Measure for a few seconds with A weighting to compare the average with the NIOSH and WHO guidance.

Everyday sound scale

  • 10 dBNormal breathingWHO
  • 30 dBSoft whisperingWHO
  • 40 dBLibraryWHO
  • 60 dBNormal conversationWHO
  • 80 dBDoorbellWHO
  • 85 dBHeavy traffic (inside a car)WHO
  • 90 dBShouted conversationWHO
  • 94–110 dBHeadphones at maximum volume, concerts, sporting eventsNIDCD
  • 95 dBMotorcycleWHO
  • 100 dBHair dryerWHO
  • 105 dBCar horn at 5 metresWHO
  • 120 dBStanding near a sirenWHO
  • 130 dBJackhammerWHO
  • 140 dBAirplane taking offWHO

Sources: WHO, “Deafness and hearing loss: safe listening” (2026), and NIDCD, “Noise-Induced Hearing Loss” (2025).

About this calculator

How it measures

The browser hands over the microphone samples and the tool computes their effective (RMS) level in dBFS, that is, relative to the most the digital input can take. To get sound pressure level (dB SPL) it adds a calibration offset: dB SPL ≈ dBFS + offset.

When the microphone opens, the tool asks the browser to switch off automatic gain control, noise suppression and echo cancellation, which exist for video calls and flatten any measurement. If the browser keeps them on, you get a warning.

A-weighting is applied with digital filters (a cascade of IIR sections) designed from the IEC 61672-1:2013 formulas for your device's sample rate. You can also pick C (more sensitive to bass) or Z (unweighted). The fast response uses 125 ms and the slow one 1 s, as on a sound level meter.

How to read the result

“Level now” is the level with the chosen response. Minimum and maximum are that level's extremes during the session. The average is Leq, the equivalent continuous level: an energy average, not an average of decibels, so a few very loud seconds weigh a lot. For example, 5 seconds at 60 dB and 5 at 70 dB give an Leq of about 67 dB, not 65.

Decibels are logarithmic: +3 dB is twice the sound energy and +10 dB ten times as much. That's why the everyday sound scale helps: according to WHO, normal conversation is about 60 dB, a motorcycle 95 dB and a hair dryer 100 dB.

If the clipping warning appears, the sound is louder than the microphone can capture and the real level is higher than shown.

Calibrating the microphone

No phone or computer microphone comes calibrated for measurement, and sensitivity varies a lot between models. Until you calibrate, the figure uses a generic 100 dB offset (0 dBFS ≈ 100 dB) that doesn't belong to any particular microphone: treat it as an estimate that can be off by 10 dB or more.

To calibrate, put the device next to a real sound level meter, with a steady sound (a fan, pink noise from a speaker) and the same weighting. Type what the meter reads and press “Match”. The offset is saved only in your browser, for that device. If you change microphones, calibrate again.

Noise exposure: what NIOSH and WHO say

The US NIOSH recommends that workers stay under 85 dBA as an 8-hour average, with a 3 dB exchange rate: every 3 dB more halves the time (88 dBA, 4 hours; 100 dBA, 15 minutes). With A-weighting, the tool works out the daily time to that limit for your Leq and how much of the daily dose the session used.

For recreational listening, WHO says 80 dB can be listened to for up to 40 hours a week and 90 dB for only 4 hours. NIDCD (US National Institutes of Health) notes that sounds at or below 70 dBA are unlikely to cause hearing loss, while long or repeated exposure at or above 85 dBA can.

These figures are for information: they assume a steady level and a calibrated microphone. They don't replace a dosimeter or an occupational hygiene assessment and aren't valid for workplace compliance.

Common uses

Compare a neighbour's or the street's noise at different times and keep the log as CSV (one value per second, with UTC time); check whether one air conditioner, extractor fan or appliance is louder than another; see how much closing a window helps; or check the level of a band rehearsal. For the CSV, keep the page visible: if the tab goes to the background, the browser slows readings and that stretch is estimated from samples.

Important limitations

  • Uncalibrated, the result is an estimate: the microphone, the phone case and system processing can shift it by 10 dB or more.
  • Phone and laptop microphones pick up deep bass and very loud sounds poorly; above their limit the signal clips.
  • It isn't a certified sound level meter (IEC 61672 class 1 or 2) or a dosimeter: it isn't suitable for inspections, formal complaints or workplace compliance.
  • Exposure figures assume a steady level; real noise varies and depends on the distance to the source.

Frequently asked questions

Uncalibrated, not enough for official purposes: phone microphones aren't calibrated and the system may process the audio. It's very good for comparing (more or less noise, before and after) and, calibrated against a real meter, gets fairly close at moderate levels.

It's the A-weighted level, which turns down deep bass and extreme treble the way human hearing does at moderate levels. It's the measure used by noise exposure guidance such as NIOSH's and WHO's.

Equivalent continuous level: the steady level that would carry the same sound energy as the noise measured during the session. It's the right average for noise because it adds up energy, not decibels.

According to NIDCD, long or repeated exposure at or above 85 dBA can cause hearing loss, while sounds at or below 70 dBA are unlikely to. The louder it is, the less time it takes: NIOSH recommends 8 hours at 85 dBA but only 15 minutes at 100 dBA.

No. Sound is analysed on your device, number by number, and discarded. Nothing is recorded or sent to any server, and the session disappears when you close the page unless you download the CSV.